SATIS+
5 modes of regulation: optimal care of the newborn
- Air and skin regulation modes
- Specific modes: twins and tenderness (for skin-to-skin sessions)
- Unique medipréma modes: heating off
Newborn care and development support
- Numerous features: active and servo-controlled humidification system, scale, radio cassette drawer, etc.
- Options: O² servo-control, balance, variable height, outgoing and rotating plate…
- Accessories: hose support arm, respirator, day/night cover, examination light, etc.
Perfect visibility of the child and numerous accesses
- Optimum transparency of the Plexiglas interior
- Numerous other accesses to the child via doors and portholes
11 holes for the passage of sensors and hoses
Advanced ergonomics optimized for care
The interior of the Satis + incubator by médipréma has been designed so that the nursing staff can easily access the child thanks to its two large drop-down doors with portholes and a double door on the head and foot sides. The numerous openings in the passenger compartment make it possible to optimise the care given to the child (11 holes to facilitate the passage of sensors and hoses).
The outgoing tray (rotating optional) is ideal for effortless access to the child’s head, thus promoting precise and delicate care.
On the other hand, the transparent plexiglass interior ensures perfect visibility of the child on 5 sides.
The incubator is equipped with plenty of storage space and is available in a height-adjustable version to optimize the working position of medical teams.
A reliable and intuitive thermoregulation and humidification system without compromising the child’s comfort
The Satis + closed incubator from médipréma has a precise, reliable and intuitive thermoregulation system with five temperature control modes.
There are air and skin control modes, present on all medipréma incubators, to which are added the Heating Shutdown mode which allows the thermo-hygrometric regulation of the incubator to be stopped while maintaining the renewal of the air in the passenger compartment (the monitoring of the child’s skin temperature remains possible), the twin mode adapted to the simultaneous monitoring of two newborns via two skin probes and the tenderness mode which secures skin-to-skin sessions.
Médipréma has designed a unique head-to-head (and not frontal) ventilation system that directs warm air along the walls of the passenger compartment, thus ensuring that the required temperature is maintained inside. It also promotes safe access to the child when opening doors without the risk of burns. The Satis+ Neonatal Resuscitation Incubator benefits from a servo-controlled humidification system (automatic mode available) with easy access to the water tray and a visual and audible alarm in case of lack of water in the tank.
These different modes are easily programmable thanks to the incubator’s intuitive color LCD touch screen that allows real-time information to be viewed in the form of a curve. It also provides good visibility of settings and alarms with the ability to mute contactless alarms (all saved data can be accessed on PC for processing or storage).
Ease of use
Highly intuitive, touch-sensitive colour LCD display with lock button
Alarm inhibition by detecting hand proximity
Optional foot alarm stop
Designed to reduce the risk of infection
All elements accessible for cleaning – no seals on the windows
Compatible with steam/autoclave cleaning
Removable water tray, with automatic cleaning mode
PERFORMANCE
THERMAL REGULATION:
- Air mode: regulation from 20 to 39°C (with safe extension below 28°C and above 37°C).
- Cutaneous mode: regulation from 35 to 39°C (with safe extension beyond 37°C).
- Tenderness Mode: mode adapted to skin-to-skin sessions
- Twin mode: control mode suitable for simultaneous monitoring of 2 newborns
- Heating shutdown mode: stop the thermo-hygrometric regulation of the incubator with maintenance of air renewal in the passenger compartment and monitoring of the child’s skin temperature.
Fast and safe temperature rise without exceeding the set temperature. Use of Pt1000 platinum resistance temperature sensors, which vary almost entirely over time, which makes the control system more reliable.
ACTIVE AND SERVO-CONTROLLED HUMIDIFICATION SYSTEM: by adjustable boiling from 35% to 90% (with safe extension beyond 80%).
Automatic mode also available.
Removable water tray with water level visibility. Alarm running out of water. Automatic cleaning mode.
OXYGEN INLET
BUILT-IN OXYGEN ANALYZER (optional) with measuring scale from 0 to 100% with low and high thresholds adjustable from 20 to 99%.
SERVO-CONTROLLED OXYGEN CONTROL (option): servo-controlled oxygen delivery system maintaining a regulated environment between 21 and 65% oxygen with high and low alarms.
3 groups of visual and audible alarms have been defined according to the degree of urgency of intervention for the comfort of the newborn and the medical team. Crescendo of alarms.
AMBIENT NOISE LEVEL EXCEEDANCE ALERT: allows teams to be informed of the increase in the sound level of the child’s environment compared to a preset target level. Allows all necessary measures to be taken to restore an acceptable ambient sound level.
HEATING POWER: 380 watts (power consumption: 800 VA)
POWER SUPPLY: 220-240V 50/60 Hz
ELECTRICAL CLASS I
NOISE LEVEL≤ 45 ±3 dB(A)
NETWORKING with data transmission according to Itherm protocol
DESCRIPTION
7”WIDE COLOUR TFT TOUCH SCREEN: on the head-side pole (2 positions possible, right or left), remote at eye level and adjustable for better visibility of data and alarms (visible over 360°).
Possibility to view information in the form of curves in real time (monitoring).
All recorded patient data can be downloaded to a USB stick for processing or archiving.
DAY/NIGHT SCREEN BRIGHTNESS
CONTACTLESS ALARM MUTING: detection of hand proximity by optical sensor
Foot alarm mute version available as an option.
SPACIOUS INTERIOR (LxWxH 890x455x500 mm) in bisphenol-free PMMA with perfect visibility on all 5 sides and plenty of access to the child.
- Front and back: 2 cut sides. 2 large drop-down doors with 2 portholes.
- Head and foot sides: 1 double door
ERGONOMIC HINGED LOCKS: to considerably reduce the noise caused by window openings, to provide greater visibility in the passenger compartment, to allow the windows to be opened with the elbows without hygiene faults.
11 ORIFICES facilitate the passage of sensors and hoses.
COMFORTABLE SLEEPING SURFACE: Anti-bedsore memory foam mattress, welded bi-elastic polyurethane cover (LxWxH 620×390 x30 mm)
ELECTRIC PROCLIVE/DECLIVATE continuously adjustable from the outside from +15° to -5°
RADIO CASSETTE DRAWER
INTEGRATED APPROVED ELECTRONIC SCALE with memory (optional)
OUTGOING PLATEAU at 75%
TURNTABLE (0-90°) allowing optimized access to the child’s head, thus facilitating precise and delicate care (option)
FLOOR/SLEEPING SURFACE HEIGHT: 1000-1200mm (HV model).
The free travel allows you to optimize the working position.
ACCESSORY RAILS on the head side.
CHASSIS EQUIPPED WITH 4 SWIVEL CASTORS (diameter 125mm) 2 of which have brake.
OVERALL DIMENSIONS: LxWxH max version HV1467x630x1368-1568 mm.
WEIGHT: (HV version not equipped) 90 kg.
OPTIONS & ACCESSORIES
- Variable height (200mm travel)
- Lying surface rotates 90°, extends 75%, removable
- Built-in electronic scale with memory curves
- Single patient skin probe
- Repositionable hydrogel probe cover
- Built-in SpO2 monitor
- SpO2 sensor
- Integrated oxygen servo control
- O2 sensor for integrated oxygen analyzer
- O2 set (0- 15l/min flow meter, humidifier and hoses)
- Respirator hose support
- Oxygen bells
- Double wall
- Mast extension support control box
- Serum Holder Rod
- Sliding trunk on the foot side
- Swivel appliance holder tray (320 x 394 mm)
- U-shaped contour rail
- Holder for 2 bottles
- Fitted sheet for mattresses
- Gel mattresses
- Microbead positioning pad
- Wrist/ankle ties
- Day/night cover
- Dimmer LED examination light
- Data Networking Kit
Class IIB
Medical DeviceElectrical class I